When equipment can be brought down for service, check calibration of the analog source and DVPII.
See Digital Com Analog Tracking Alarm.
Byte 1-2
Bit 15
Digital Comm.
Vs Analog Tracking Shutdown
The position demand provided via the analog control signal does not match the digital demand signal within the shutdown tracking window allowed by the DVPII.
See Digital Com Analog Tracking Shutdown.
Table A-12.
PDO8 Byte 3-4 (Status Error Register 9)
Status
Byte
Bit
Status Name
Description
Troubleshooting Guide
Byte 3-4
Bit 0
Startup Close Motor 2 Error
This indicates the Motor 2 resolver did not fall within the startup min limit range.
See Startup Close Motor
Error
Byte 3-4
Bit 1
Startup Open Motor 2 Error
This indicates the Motor 2 resolver did not fall within the startup max limit range.
See Startup Open Motor
Error
Byte 3-4
Bit 2
Startup Direction Motor 2 Error
This indicates the Motor 2 resolver did not rotate sufficiently or rotated in the incorrect direction.
See Startup Direction Motor Error
Byte 3-4
Bit 3
Startup Open Shaft 1 Failed
This indicates the primary final element position sensor (shaft 1) or the secondary final element position sensor (shaft 2) did not fall within the startup max limit range.
See Startup Open Valve Shaft 1 Error

Proposed translations

7 mins
Selected

Ошибка направления вращения эл/двигателя 2 при пуске

.
Something went wrong...
4 KudoZ points awarded for this answer.
11 hrs

*

ошибка направления вращения датчика 2 (резольвера, СКВТ) (на вале) двигателя привода в режиме пуска турбины
https://www.woodward.com/-/media/publication-assets/technica...
Automatic Start Sequence to start the turbine. This sequencing
logic allows the 505 to perform a complete controlled system start-up from zero speed to rated speed.
With this function, the turbine’s starting ramp rates and idle speed hold times depending on either the
length of time the unit was shut down or upon optional temperature input signals
http://www.rtd-universal.com/files/374596720-40185_J.pdf
The turbine control analog demand to the driver should be
calibrated to verify that the proper 4 mA to 20 mA signal is
provided.

--------------------------------------------------
Note added at 12 hrs (2019-12-10 01:53:49 GMT)
--------------------------------------------------

This indicates the primary final element position sensor (shaft 1) or the secondary final element position sensor (shaft 2) did not fall within the startup max limit range.
See Startup Open Valve Shaft 1 Error
вал состоит из двух частей, соединенных предохранительной муфтой
http://www.rtd-universal.com/files/374596720-40185_J.pdf
actuator consists of a high
performance brushless servomotor and a precision planetary gearbox with two
resolver-type shaft position sensors
...
The motor output shaft is directly coupled to the valve input shaft
through the use of a stainless steel torsional coupling.
Something went wrong...
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search