Before arranging an integrity test, thoroughly inspect the perimeter of the enclosure and make good any potential gas leakage paths.
Carry out test of enclosure integrity using the method given in BS 5306, Section 5.1 :1992, Appendix A.
Carry out test of enclosure integrity using the method given in BS 5306, Section 5.1 :1992, Appendix A.
Proposed translations
(Hungarian)
4 +1 | légáteresztő összterület kiszámítása légáteresztéses vizsgálat segítségével | Katalin Szilárd |
Change log
Dec 21, 2009 10:21: Katalin Szilárd changed "Edited KOG entry" from "<a href="/profile/668248">etike's</a> old entry - "(enclosure) integrity test"" to ""légáteresztő összterület kiszámítása légáteresztéses vizsgálat segítségével""
Proposed translations
+1
1 hr
Selected
légáteresztő összterület kiszámítása légáteresztéses vizsgálat segítségével
A légáteresztéses vizsgálat (blower door test) és az enclosure integrity test szinte dettó ugyanaz. Annyi a különbség, hogy míg a blower doornál a zárt helységből távozó levegő óránkénti mennyiségét számítják ki, addig az enclosure testnél a "lyukas" (légáteresztő területek) mennyiségét számítják.
Lásd leírások és képek:
http://www.infiltec.com/inf-ha.htm#Specifications
"Infiltec's experience in air leakage test equipment development enabled it to invent a test that solved this problem. The "enclosure integrity test" involves measuring the total area of the holes in the protected room with a blower door, assuming a worst-case distribution of leaks across the enclosure surface, and computing the worst-case leakage of the fire protection gas mixture through those holes. David Saum and Arthur Saum of Infiltec were issued US patent #5,128,881 Means and Methods for Predicting Hold Time in Enclosures Equipped with a Total Flooding Fire Protection Fire Extinguishing System for this work. This test was incorporated into the NFPA 12A Standard for halon 1301, and it has since been modified for halon alternative gases in the NFPA 2001 Standard. "
http://www.energyconservatory.com/applications/applications6...
"NFPA Enclosure Integrity Testing
Enclosure integrity testing uses a Blower Door to measure the total leakage area of rooms protected by fire suppression systems. The measured leakage area from the Blower Door test can then be used to estimate retention times for various clean agent fire extinguishing systems installed in the protected room. Procedures for conducting enclosure integrity tests with a Blower Door are contained in Appendix C of NFPA 2001."
http://www.airpressuretesting.net/fire_integrity_testing.htm
http://www.kontravill.hu/blowerdoor/blowerdoor_m.html
Lásd leírások és képek:
http://www.infiltec.com/inf-ha.htm#Specifications
"Infiltec's experience in air leakage test equipment development enabled it to invent a test that solved this problem. The "enclosure integrity test" involves measuring the total area of the holes in the protected room with a blower door, assuming a worst-case distribution of leaks across the enclosure surface, and computing the worst-case leakage of the fire protection gas mixture through those holes. David Saum and Arthur Saum of Infiltec were issued US patent #5,128,881 Means and Methods for Predicting Hold Time in Enclosures Equipped with a Total Flooding Fire Protection Fire Extinguishing System for this work. This test was incorporated into the NFPA 12A Standard for halon 1301, and it has since been modified for halon alternative gases in the NFPA 2001 Standard. "
http://www.energyconservatory.com/applications/applications6...
"NFPA Enclosure Integrity Testing
Enclosure integrity testing uses a Blower Door to measure the total leakage area of rooms protected by fire suppression systems. The measured leakage area from the Blower Door test can then be used to estimate retention times for various clean agent fire extinguishing systems installed in the protected room. Procedures for conducting enclosure integrity tests with a Blower Door are contained in Appendix C of NFPA 2001."
http://www.airpressuretesting.net/fire_integrity_testing.htm
http://www.kontravill.hu/blowerdoor/blowerdoor_m.html
Note from asker:
köszönöm szépen a kimerítő választ! |
Peer comment(s):
agree |
Balázs Sudár
12 mins
|
Köszönöm!
|
|
neutral |
juvera
: A magyarázatod félrecsúszott: a teszt ugyanaz, a mérések felhasználhatók külünböző célokra. Tűzbiztonság szempontjából az óránkénti légáteresztés - retention time - mennyisége a fontos. A helyes válasz: "légáteresztés vizsgálat". Ld. ref.
42 mins
|
Szerintem nem csúszott félre. Én is azt mondtam, hogy a teszt ugyanaz, csak mást számítanak ki vele.
|
4 KudoZ points awarded for this answer.
Discussion
Érdemes ezeket megnézni:
www.kontravill.hu/blowerdoor/blowerdoor_m.html
en.wikipedia.org/wiki/Blower_door